A compact 130 mm PWL-F configuration for continuous tank-level indication inside automated industrial equipment
130 mm probe | 0-10 V, 3-wire | 24 VDC PLC | HMI 0-100% | Water service

PWL-F project variants with stainless-steel stems and blue magnetic PP floats.
Features
Customized 130 mm probe for the machine's compact water tank.
0-10 V three-wire output for direct PLC analog-input integration.
16-32 VDC project supply range, compatible with the available 24 VDC control power.
SAE 5-hole flange, 7 mm accuracy and a compact 8 mm stainless-steel probe.
SUS304 wetted stem and magnetic PP float selected for regular water service.
Background
This Portugal company designs automation machinery and customized production equipment for the electronics industry, their machines are exported to worldwide. One machine needed continuous level indication for an internal water service tank.
The atmospheric tank operates near 25°C without significant pressure or vibration. A separate overflow opening diverts excess water to a second tank.

Customer-supplied PWL-F-130 installation inside the machine.
Measurement Requirements
Requirement | Application definition |
Medium | Water in an atmospheric machine tank |
Ambient condition | Approximately 25°C; no applied pressure or vibration |
Level function | Continuous level feedback for low-level awareness and operator display |
Control interface | Three-wire 0-10 V signal to the machine PLC analog input |
Power | 24 VDC machine supply |
Display | PLC scaling to 0-100% on the HMI |
Independent safeguard | Overflow opening routes excess water to a second tank |
Pokcenser Solution
Pokcenser configured a 130 mm PWL-F with 0-10 V three-wire output for the customer's 24 VDC control system. The PLC scales the analog signal to a 0-100% HMI level display.
WATER TANK -> PWL-F FLOAT POSITION -> 0-10 V -> PLC ANALOG INPUT -> HMI 0-100%
The SAE 5-hole flange fits the compact tank. The probe is mounted vertically and clear of the tank wall, inlet turbulence and obstructions; the overflow remains an independent safeguard.
Verified Result
After installation, the customer confirmed correct operation through the PLC analog input, with the HMI displaying tank level from 0 to 100%.
"We have the float level sensor connected to our PLC by analog connection, and it works properly."
PLC and HMI Integration

The PLC scales the analog signal for a 0-100% water-level indication on the machine HMI.
Material Compatibility with Water
SUS304 provides suitable corrosion resistance for the clean, unheated fresh water in this atmospheric tank near 25°C. The PP float has low water absorption and good corrosion and chemical resistance for normal water immersion within 0-60°C.
Customer Benefits
Direct 0-10 V connection to the existing PLC without a separate communication gateway.
Clear 0-100% HMI display instead of relying only on a low-level on/off alarm.
Compact, water-compatible construction matched to the tank; the overflow remains an independent backup.
Product Used
Product item | Supplied configuration |
Model | PWL-F float type level sensor |
Medium & conditions | Water; atmospheric pressure; 0 to 60°C |
Probe length | 130 mm |
Output | 0-10 V, three-wire |
Project supply range | 16-32 VDC; operated from the machine's 24 VDC supply |
Mounting | SAE 5-hole flange |
Accuracy | 7 mm project configuration |
Probe | 8 mm diameter, SUS304 stainless steel |
Float | 26 x 26 x 9.5 mm, blue magnetic polypropylene (PP) |
Project values follow the supplied order specification; use the approved project drawing as the production reference for this 0-10 V configuration.