Email Us

After-sales Service

pokcenser after sales service process and response time
Pokcenser After-Sales Service Process and Response Time
  • Submit the request. Send the product model, serial number, order reference, application medium, range, wiring, controller details, photos or video, and a clear description of the symptom.

  • Confirm the case. Our team checks whether the issue concerns selection, installation, configuration, process conditions, transport damage or a possible product fault. Urgent production-stop cases are prioritized according to available information and time zone. We response within 1 hour to 24 hours.

  • Remote diagnosis. Support may include wiring checks, parameter review, installation assessment, signal testing and controlled troubleshooting steps. Customers should not open explosion-protected or sealed products unless specifically authorized.

  • Resolution plan. Depending on the diagnosis and warranty status, the next step may be configuration guidance, replacement accessories, return inspection, repair or replacement.

  • Case closure. After the solution is verified, key findings are recorded so the customer can avoid recurrence. Resolution time varies with case complexity, response speed, parts availability and international shipping.

technical support channels for global customers
Technical Support Channels for Global Customers

Sales and application inquiries: info@pokcenser.com

Technical support: support@pokcenser.com

WhatsApp/WeChat: +86 181 7515 5326


Support can be provided through email, instant messaging, shared photos or video, product manuals, wiring diagrams and scheduled remote meetings. Email is recommended for complex cases because it preserves the model, serial number, files and troubleshooting history in one record.


To shorten diagnosis time, send all available evidence in the first message: nameplate photo, overall installation photo, close-up of the process connection, wiring diagram, power-supply reading, PLC scaling, parameter screenshots, actual process conditions and a short video of the symptom. Never send confidential access credentials. For hazardous or pressurized installations, make the process safe before inspection or removal.

troubleshooting common sensor and instrument issues
Troubleshooting Common Sensor and Instrument Issues
  • No output: verify supply voltage, polarity, loop resistance, terminal assignment, cable continuity and controller input type.

  • Unstable reading: check process fluctuation, grounding, shielding, electrical interference, vibration, bubbles, foam, poor sensor location or loose wiring.

  • Incorrect scaling: confirm lower and upper range values, engineering units, PLC conversion and digital register interpretation.

  • Level false echoes: review nozzle length, blanking distance, internal obstructions, antenna alignment, agitation and echo settings.

  • Flow reading error: confirm the pipe is full, flow direction, grounding, straight run, pipe data and ultrasonic signal quality.

  • Water-quality drift: inspect fouling, calibration solution, temperature compensation, flow conditions and consumable life.

Before changing parameters, save the original configuration. Do not perform electrical work in a hazardous area or remove an instrument from a pressurized process without following the site safety procedure.


WeChat QR Code
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Visit our cookie policy to learn more.
Reject Accept