An engineering company from Brazil contacted us to find a flow measurement solution for animal fat. Their requested information is as below:
Diameter: DN 10" – 150 LBS
Pressure: 4.5 bar(g)
Flow rate: 340 m³/h
Temperature: 50°C
The fluid will be animal fat for dispatch/export operations.
Pokcenser asked more details about viscosity, density, and if there is thermal insulation, if fluid always in running status even in winter, and what is the typical flow rate and maximum flow rate. So we got more information:
1. The approximate viscosity is 30 to 50 cSt (centistokes) kinematic viscosity, or approximately 25 to 45 mPa·s (millipascal-seconds) absolute/dynamic viscosity.
2. The animal fat will be maintained in liquid form even during winter conditions. The system includes thermal insulation and an active heating process. The fat will be kept at approximately 50 °C throughout the transfer line and at the flow meter to ensure it remains fully liquid during operation.
3. The typical density of the animal fat under operating conditions (around 50 °C) is approximately 900 kg/m³.
4. The typical operating flow rate will be approximately 335 m³/h. This value is based on the actual operating conditions of the system. The installed pumps have a maximum capacity of 400 m³/h, which represents the maximum possible flow rate, but not the normal continuous operating flow.
With those information our engineering team had the technical evaluation that a DN100 coriolis mass flow meter was suitable and can cover the max capacity of flow rate. The pressure drop is ≤50KPa. The cost was much more favorable for DN100 rather than DN250. Client was very satisfied with it because of tight budget for this project.
Our Coriolis mass flow meter has ± 0.15 % FS accuracy, SS316L wetted part, and 4-20mA+0-10KHz+RS485 MODBUS signal output that helpful in programming the PLC for batching, alarm and recipe control.