The limited warranty applies to Pokcenser products that are defective in materials or workmanship, or that do not conform to the confirmed order specification, subject to inspection and the agreed terms. Covered product groups may include flow meters, level sensors, pressure transmitters, temperature sensors, temperature sensors and related devices supplied by Pokcenser.
The warranty does not cover damage or malfunction caused by incorrect selection, incompatible media, improper installation or removal, operation outside the rated limits, unauthorized modification or repair, misuse, neglect, corrosion not covered by the confirmed material selection, excess moisture, fire, lightning, power surge, accident, unsuitable storage or packing, transport damage, normal wear or force majeure.
Consumable items, calibration drift caused by normal use and damage to electrodes, membranes, cables or seals may be excluded unless a manufacturing defect is confirmed. Always refer to the product datasheet, order confirmation and project-specific agreement for the exact scope.
The standard limited warranty for Pokcenser products is twelve (12) months from the manufacturing date unless a different period is confirmed in the quotation, contract or order acknowledgement. Customers who require an 18-, 24- or 36-month extended warranty should request it before commercial confirmation so pricing, service scope and conditions can be agreed in writing.
Warranty coverage is linked to the original supplied product and verified order. Repair or replacement does not automatically restart the full warranty period unless stated in the applicable agreement. Technical support for installation, configuration and troubleshooting may continue beyond the limited warranty, but parts, repair, calibration, inspection and freight can be chargeable after the warranty expires or when the failure is outside coverage.
Before returning any product, contact Pokcenser for technical review and return authorization. Provide:
Product model and serial number
Invoice, order or shipment reference
Date the issue was first observed
Medium and actual operating conditions
Wiring, power supply and controller information
Photos of the nameplate and installation
Video, readings, alarm codes or test results
Description of troubleshooting already completed
Decontamination declaration when the product contacted process media
Pokcenser will review the evidence and may request additional tests. If return inspection is required, the product must be safely cleaned, packed and shipped according to the return instructions. After inspection, Pokcenser will advise whether the claim qualifies for repair, replacement, credit or another agreed resolution. Freight, customs and on-site costs depend on the confirmed claim result and sales terms.
Access flow, level, pressure, temperature, liquid-analysis and wireless IoT products for multiple industries and applications.
Distributor pricing supports attractive margins and local competitiveness.
Receive assistance with product selection, configuration and troubleshooting.
Use Pokcenser brand, catalogues, datasheets, certificates and application materials.
Gain opportunities for project support, customized solutions and market development.
Strong opportunities exist in water supply, wastewater treatment, agricultural irrigation, industrial automation and tank monitoring. Local distributors can serve contractors, system integrators, factories and infrastructure projects.
Target applications include water storage, deep wells, fuel tanks, oil and gas facilities, mining and remote monitoring. Wireless and low-maintenance measurement solutions are particularly suitable for widely distributed sites.
Potential markets include mining, water treatment, agriculture, food processing, energy and industrial production. Regional partners can combine Pokcenser products with local engineering, installation and after-sales services.
Opportunities focus on OEM integration, replacement instruments, customized outputs and specialized measurement applications. Partners with strong technical capabilities can develop customers requiring reliable products, documentation and application support.
Partners receive training on product principles, specifications, selection methods, installation requirements and typical industrial applications.
Pokcenser assists with reviewing the medium, range, materials, process conditions, output and installation before recommending a suitable model.
Priority production arrangement for both samples and bulk quantity orders.
Suitable local enquiries and smaller customers may be referred to the authorized distributor, allowing the distributor to contact, quote and serve them directly.
Pokcenser provides remote assistance with wiring, parameter settings, installation, troubleshooting and warranty evaluation.
Registered projects may receive coordination support to reduce channel conflicts and protect the distributor's legitimate project development efforts.
Partners can use Pokcenser catalogues, datasheets, certificates, application guides, product images and other approved promotional materials.
Sample or demonstration requirements can be discussed according to the project and cooperation plan. Distributors will also receive relevant product updates and additional training materials.
Submit the request. Send the product model, serial number, order reference, application medium, range, wiring, controller details, photos or video, and a clear description of the symptom.
Confirm the case. Our team checks whether the issue concerns selection, installation, configuration, process conditions, transport damage or a possible product fault. Urgent production-stop cases are prioritized according to available information and time zone. We response within 1 hour to 24 hours.
Remote diagnosis. Support may include wiring checks, parameter review, installation assessment, signal testing and controlled troubleshooting steps. Customers should not open explosion-protected or sealed products unless specifically authorized.
Resolution plan. Depending on the diagnosis and warranty status, the next step may be configuration guidance, replacement accessories, return inspection, repair or replacement.
Case closure. After the solution is verified, key findings are recorded so the customer can avoid recurrence. Resolution time varies with case complexity, response speed, parts availability and international shipping.
Sales and application inquiries: info@pokcenser.com
Technical support: support@pokcenser.com
WhatsApp/WeChat: +86 181 7515 5326
Support can be provided through email, instant messaging, shared photos or video, product manuals, wiring diagrams and scheduled remote meetings. Email is recommended for complex cases because it preserves the model, serial number, files and troubleshooting history in one record.
To shorten diagnosis time, send all available evidence in the first message: nameplate photo, overall installation photo, close-up of the process connection, wiring diagram, power-supply reading, PLC scaling, parameter screenshots, actual process conditions and a short video of the symptom. Never send confidential access credentials. For hazardous or pressurized installations, make the process safe before inspection or removal.
No output: verify supply voltage, polarity, loop resistance, terminal assignment, cable continuity and controller input type.
Unstable reading: check process fluctuation, grounding, shielding, electrical interference, vibration, bubbles, foam, poor sensor location or loose wiring.
Incorrect scaling: confirm lower and upper range values, engineering units, PLC conversion and digital register interpretation.
Level false echoes: review nozzle length, blanking distance, internal obstructions, antenna alignment, agitation and echo settings.
Flow reading error: confirm the pipe is full, flow direction, grounding, straight run, pipe data and ultrasonic signal quality.
Water-quality drift: inspect fouling, calibration solution, temperature compensation, flow conditions and consumable life.
Before changing parameters, save the original configuration. Do not perform electrical work in a hazardous area or remove an instrument from a pressurized process without following the site safety procedure.