Choose the correct pressure reference before selecting a range, process connection, or output signal.

QUICK ANSWER Pressure type is defined by its reference. Gauge pressure compares the process with current atmosphere. Absolute pressure compares it with a sealed vacuum reference. Sealed-gauge pressure compares it with a sealed nominal atmospheric reference. Compound and vacuum ranges express pressure below atmosphere, while differential pressure compares two connected process points. Selecting the wrong reference creates a systematic error.
Three Reference Equations
Let Pabs be absolute process pressure, Patm the local atmospheric pressure, and P1 and P2 two process pressures. The basic relationships are: Pg = Pabs − Patm, Pabs = Pg + Patm, and ΔP = P1 − P2. Atmospheric pressure changes with elevation and weather, so it matters whenever the sensor reference is atmosphere.
Definitions and Typical Uses
Pressure type | Reference | Typical use |
Gauge | Current local atmosphere through a vent | Hydraulics, water lines, compressed air, open tanks |
Absolute | Permanent internal vacuum | Barometric pressure, vacuum systems, gas calculations, sealed vessels |
Sealed-gauge | Sealed nominal atmospheric reference | High-pressure mobile or hydraulic service where venting is undesirable |
Compound | Atmosphere, with range below and above zero gauge | Pump suction/discharge cycles, systems alternating between vacuum and pressure |
Vacuum | Atmosphere, showing pressure below atmosphere | Suction, vacuum packaging, leak testing, vacuum pumps |
Differential | A second connected process pressure | Filter condition, flow elements, pressurized tank level, clean-room pressure |
Gauge Pressure
A gauge sensor vents its reference side to the surrounding atmosphere. It reads approximately zero when the process port is open to the same atmosphere. This is the usual choice when operators care how far a tire, pipe, or hydraulic circuit is above ambient pressure. The vent must remain dry and unobstructed.
Absolute and Sealed-Gauge Pressure Are Not the Same
An absolute sensor contains a vacuum reference, so its reading does not follow weather or altitude. A sealed-gauge sensor contains a sealed reference captured near a nominal atmospheric pressure. At high process pressures the difference from live atmosphere may be small relative to span, but at low ranges it can be important. Do not describe sealed gauge as absolute.
Compound and Vacuum Ranges
A vacuum gauge normally reports how far the process is below atmosphere, often using negative gauge pressure or vacuum units. A compound range crosses atmospheric zero—for example, −1 to +3 bar gauge. It is useful when the same port experiences suction during one operating state and positive pressure during another.
Differential Pressure
A differential-pressure transmitter has high- and low-pressure connections and reports their difference. Both sides may be at substantial static pressure even when ΔP is small. Selection must therefore cover the differential span, static line pressure, overpressure direction, and manifold sequence. Common applications include filter loading, orifice flow, closed-tank level, and room-pressure monitoring.
Selection Checklist
1. State what zero must mean: local atmosphere, perfect vacuum, a sealed reference, or another process point.
2. List minimum, normal, maximum, vacuum, and transient pressures in one consistent reference.
3. Confirm whether elevation or weather changes should affect the result.
4. For DP, specify both static line pressure and the smallest differential span.
5. Choose a range that covers credible transients without sacrificing useful resolution.
6. Mark the pressure reference in the model description, calibration record, PLC tag, and drawing.
Engineering Illustration

Why does an absolute sensor not read zero in open air?
Because it measures atmospheric pressure above perfect vacuum. Near sea level, an open absolute sensor reads roughly one atmosphere, not zero.
When is sealed gauge useful?
It is common in rugged high-pressure service where an atmospheric vent would invite moisture or contamination and small atmospheric changes are negligible relative to span.
Can a DP transmitter measure gauge pressure?
Some configurations can use one side as an atmospheric reference, but the port arrangement, static limits, vent protection, and calibration must match the intended measurement.