Selecting the correct lining material for an electromagnetic flow meter is critical for ensuring long-term measurement accuracy, corrosion resistance, and equipment lifespan. Different industrial applications — from wastewater treatment to chemical processing and mining slurry measurement — require different lining materials based on temperature, pressure, corrosion level, and abrasion resistance.
At Pokcenser, we help industrial users choose the most suitable electromagnetic flow meter configuration for harsh operating environments, improving reliability while reducing maintenance costs.

The lining inside an electromagnetic flow meter directly contacts the measured liquid. A poor lining choice may lead to:
Corrosion damage
Reduced measurement accuracy
Premature sensor failure
Frequent maintenance downtime
Increased operating costs
Choosing the proper lining material ensures stable performance even under aggressive chemical, abrasive slurry, or high-temperature conditions.
Good aging resistance
Moderate acid and alkali resistance
Excellent elasticity
Economical and cost-effective
CR lining is suitable for:
Industrial water
Wastewater treatment
Weak acid and weak alkali liquids
General-purpose flow measurement
Affordable
Good wear resistance
Suitable for municipal water projects
Not suitable for strong corrosive chemicals
Extremely high wear resistance
Excellent elasticity
Abrasion resistance up to 10 times higher than natural rubber
Poor resistance to strong acids and alkalis
PU-lined electromagnetic flow meters are ideal for:
Mining slurry
Ore pulp
Coal-water slurry
Muddy water
Sand-containing liquids
For abrasive industrial environments, Pokcenser PWF-E1200 Electromagnetic Flow Meter provides reliable slurry measurement performance with durable lining options.
Excellent anti-abrasion performance
Ideal for mining industries
Long service life in slurry applications
Maximum operating temperature generally below 80°C
Limited chemical resistance
Outstanding chemical resistance
Resistant to most acids, alkalis, and solvents
Wide temperature tolerance (-200°C to +260°C)
Smooth non-stick surface
PTFE-lined electromagnetic flow meters are widely used in:
Chemical processing
Acid dosing systems
Pharmaceutical industries
Food-grade corrosive liquids
The Pokcenser Sanitary Electromagnetic Flow Meter PWF-E1220 is ideal for hygienic and corrosive liquid applications requiring high chemical compatibility.
Superior corrosion resistance
Excellent high-temperature performance
Suitable for aggressive chemicals
Lower abrasion resistance
Weaker vacuum resistance
Similar chemical resistance to PTFE
Better wear resistance than PTFE
Improved negative pressure resistance when reinforced
Suitable for:
Corrosive liquids with moderate abrasion
Vacuum operating conditions
Chemical transportation systems
Improved durability
Better vacuum resistance
Good balance between corrosion and wear resistance
Excellent chemical resistance
High-temperature capability
Smooth and easy-to-clean surface
Suitable for sanitary applications
PFA lining is ideal for:
High-purity chemical processing
Pharmaceutical production
Food and beverage industries
High-temperature corrosive fluids
High purity
Easy cleaning
Excellent thermal stability
Extremely high hardness
Outstanding wear resistance
Excellent corrosion resistance
Stable under high temperature and pressure
Ceramic-lined electromagnetic flow meters are recommended for:
Highly abrasive slurry
Solid-particle fluids
Mining applications
Harsh chemical environments
The Pokcenser PWF-E1200S Split Type Electromagnetic Flow Meter offers durable ceramic lining options for demanding industrial applications.
Exceptional durability
Corrosion-proof performance
Long-term dimensional stability
Higher initial investment cost
When choosing an electromagnetic flow meter lining, consider the following factors:
| Working Condition | Recommended Lining |
| Weakly corrosive water | CR Rubber |
| Abrasive slurry | PU Rubber / Ceramic |
| Strong acids & alkalis | PTFE / PFA |
| High-temperature chemicals | PTFE / PFA |
| Vacuum environments | Reinforced F46 |
| Hygienic applications | PTFE / PFA |
At Pokcenser, we provide industrial electromagnetic flow meters designed for:
Chemical processing
Water treatment
Mining slurry measurement
Food & beverage industries
Pharmaceutical production
Our flow meters support multiple lining materials and customized configurations to match complex industrial conditions.
Benefits include:
High measurement accuracy
Stable long-term operation
Corrosion-resistant designs
Fast delivery and technical support
OEM & ODM customization
PTFE and PFA are the most commonly used lining materials for highly corrosive acids and alkalis because of their excellent chemical resistance.
Polyurethane rubber and ceramic linings are ideal for slurry applications due to their superior abrasion resistance.
Yes. PTFE can typically operate between -200°C and +260°C, making it suitable for high-temperature chemical applications.
For highly abrasive or corrosive applications, ceramic lining significantly extends service life and reduces maintenance costs, making it cost-effective over time.
You should evaluate:
Medium composition
Corrosiveness
Temperature
Pressure
Presence of solid particles
Installation environment
Professional selection support from suppliers like Pokcenser can help ensure optimal performance.