    When comparing industrial sensors, one of the first specifications engineers notice is accuracy.

    Manufacturers often advertise specifications such as:

    • ±0.5%FS

    • ±0.2%FS

    • ±0.1%FS

    • ±0.075%FS

    At first glance, these numbers may seem straightforward. However, many users misunderstand what these accuracy ratings actually mean and how they affect real-world measurements.

    In this guide, we'll explain how sensor accuracy is defined, how to calculate measurement errors, and when investing in a higher-accuracy instrument makes sense.


    What Is Sensor Accuracy?

    Sensor accuracy describes how close a measured value is to the actual value.

    No measurement instrument is perfectly accurate. Every sensor has some degree of error between the measured value and the true value.

    For example:

    If the actual pressure is:

    10.0 bar

    And the transmitter displays:

    10.1 bar

    The measurement error is:

    0.1 bar

    The smaller the error, the higher the accuracy.


    What Does "%FS" Mean?

    Most industrial transmitters specify accuracy as a percentage of Full Scale (FS).

    Full Scale refers to the maximum measurement range of the instrument.

    Example:

    Pressure transmitter range:

    0-100 bar

    Full Scale (FS):

    100 bar

    If the accuracy is:

    ±0.5%FS

    The maximum error is:

    100 × 0.5%

    = ±0.5 bar

    This means the transmitter may read:

    • 9.5 bar

    • 10.0 bar

    • 10.5 bar

    when the actual pressure is 10 bar.


    How Accuracy Changes with Different Specifications

    Let's compare several common accuracy ratings using the same 0-100 bar pressure transmitter.

    Accuracy

    Maximum Error

    ±0.5%FS

    ±0.5 bar

    ±0.2%FS

    ±0.2 bar

    ±0.1%FS

    ±0.1 bar

    ±0.075%FS

    ±0.075 bar

    As accuracy improves, measurement uncertainty decreases.

    This is especially important in applications requiring precise process control.


    Why Accuracy Matters More at Lower Readings

    Many users assume that a ±0.5%FS transmitter has a 0.5% error regardless of the measured value.

    This is incorrect.

    Consider a transmitter with:

    Range:

    0-100 bar

    Accuracy:

    ±0.5%FS

    Maximum error remains:

    ±0.5 bar

    Whether the measured pressure is:

    • 10 bar

    • 50 bar

    • 90 bar

    the error limit remains the same.


    Example at 10 bar

    Actual pressure:

    10 bar

    Possible reading:

    9.5-10.5 bar

    Relative error:

    5%

    Example at 90 bar

    Actual pressure:

    90 bar

    Possible reading:

    89.5-90.5 bar

    Relative error:

    0.56%

    This is why selecting an appropriate measurement range is extremely important.


    Accuracy vs Repeatability

    These two specifications are often confused.


    Accuracy

    Measures how close a reading is to the true value.


    Repeatability

    Measures how consistently a sensor produces the same reading under identical conditions.


    Example:

    A transmitter repeatedly measures:

    • 50.1 bar

    • 50.1 bar

    • 50.1 bar

    Excellent repeatability.

    However, if the actual pressure is 49.5 bar, the accuracy is still poor.

    A good industrial instrument should provide both high accuracy and good repeatability.


    Accuracy vs Resolution

    Another common misunderstanding involves resolution.


    Resolution

    The smallest detectable change in a measurement.

    Example:

    A display showing:

    50.01 bar

    has higher resolution than a display showing:

    50.0 bar

    However, higher resolution does not automatically mean higher accuracy.

    A sensor can display many decimal places while still having significant measurement error.


    Typical Accuracy Requirements by Application

    Different industries require different levels of accuracy.

    General Water Treatment

    Recommended Accuracy:

    ±0.5%FS

    Suitable for:

    • Pump monitoring

    • Water distribution systems

    • General process control


    Tank Level Monitoring

    Recommended Accuracy:

    ±0.2%FS to ±0.5%FS

    Suitable for:

    • Water tanks

    • Wastewater tanks

    • Chemical storage tanks


    Chemical Processing

    Recommended Accuracy:

    ±0.1%FS to ±0.2%FS

    Suitable for:

    • Dosing systems

    • Reactor monitoring

    • Process optimization


    Custody Transfer and Critical Measurements

    Recommended Accuracy:

    ±0.075%FS or better

    Suitable for:

    • High-value processes

    • Energy applications

    • Precision industrial systems


    When Is a High-Accuracy Sensor Worth the Investment?

    Higher accuracy instruments generally cost more.

    However, the additional investment may be justified when:

    Product Quality Is Critical

    Small measurement errors can affect product consistency.

    Process Efficiency Matters

    Accurate measurements improve control system performance.

    Regulatory Compliance Is Required

    Many industries must meet strict measurement standards.

    Inventory Management Is Important

    Level measurement errors can affect inventory calculations.


    Recommended High-Accuracy Solution

    PWP3051DP Smart Monocrystalline Silicon Differential Pressure Transmitter

    The PWP3051DP Smart Monocrystalline Silicon Differential Pressure Transmitter offers accuracy up to ±0.075%FS, making it suitable for demanding industrial applications requiring high measurement precision.


    Key Features

    • Accuracy up to ±0.075%FS

    • Excellent long-term stability

    • HART communication

    • Suitable for liquid, gas, and steam measurement

    • Industrial-grade reliability


    Typical Applications

    • Process control systems

    • Chemical plants

    • Power generation

    • Water treatment facilities

    • Industrial automation systems


    Common Accuracy Selection Mistakes

    Choosing Accuracy Based Only on Price

    Lower-cost instruments may not provide the precision required for critical applications.

    Overspecifying Accuracy

    Not every application needs ±0.075%FS performance.

    For many water and wastewater systems, ±0.5%FS is sufficient.

    Ignoring Measurement Range

    An incorrectly selected range can have a greater impact than the accuracy specification itself.

    Overlooking Long-Term Stability

    Accuracy should be evaluated together with stability and drift performance.


    Why Choose Pokcenser?

    Pokcenser provides industrial measurement solutions for customers in more than 100 countries.

    Our product portfolio includes:

    • Pressure Transmitters

    • Differential Pressure Transmitters

    • Radar Level Sensors

    • Ultrasonic Level Sensors

    • Flow Meters

    • Water Quality Instruments

    We help customers select the most cost-effective balance between performance, reliability, and accuracy.


    Frequently Asked Questions

    Q1: Is ±0.075%FS always better than ±0.5%FS?

    Yes in terms of measurement precision, but not every application requires such high accuracy.


    Q2: Does higher accuracy always mean higher cost?

    Generally yes, because higher-accuracy sensors require better sensing elements, calibration, and manufacturing processes.


    Q3: What does FS mean?

    FS stands for Full Scale, which refers to the maximum measurement range of the instrument.


    Q4: Is accuracy more important than resolution?

    For industrial process measurement, accuracy is usually more important than display resolution.


    Q5: Which industries require high-accuracy transmitters?

    Chemical processing, power generation, pharmaceutical manufacturing, and precision industrial applications often require higher accuracy instruments.


    Understanding Sensor Accuracy


    Understanding Sensor Accuracy


    Understanding Sensor Accuracy


    Understanding Sensor Accuracy

    References

    WeChat QR Code
    We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Visit our cookie policy to learn more.
    Reject Accept