Select a hydraulic pressure sensor using normal pressure, maximum working pressure, transient spikes, and required overload capacity. PWP330 supports up to 200%FS safe overload for ranges through 60MPa and 150%FS from 70 to 250MPa. Confirm hydraulic-fluid compatibility with the 17-4PH diaphragm, process thread, sealing method, temperature, vibration, and mounting space. Match 4–20mA or voltage output, supply, connector, IP rating, and controller input. Install away from severe pulsation or add a snubber when pressure spikes may exceed the sensor rating.