PWL-U501 combines local display, gold-plated circuitry and 48-hour thermal aging with intelligent echo recognition, temperature compensation and multi-output control for dependable tank level monitoring.
Applications
Flood-control and hydrology stations
Oil storage and transfer tanks
Sewage-treatment systems
Dyeing and process pools
Water tanks and reservoirs
Industrial liquid-level alarm and control
Model | PWL-U501 |
Measuring Range | 5m, 7m, 10m, 15m |
Blind Area | ≤300mm for ≤5m range; ≤500mm for ≤7m range; ≤500mm for ≤10m range; ≤800mm for ≤15m range. |
Beam Angle | 15° for ≤5m range; 12° for ≤7m range; 12° for ≤10m range; 9° for ≤15m range; |
Accuracy | ±0.5%FS(Typical), ±0.25%FS by customized |
Signal Output | 4~20mA/0-5V/1-5V/0-10V/1-10V/RS485/RS232/Relay |
Power Supply | 24VDC/12VDC |
Consumption | <1.5W |
Resolution | 1mm |
Working Temp. | -20℃~70℃ |
Protection Level | IP66; IP68 by customization |
Housing Material | NLEPF synthetic material |
Installation Method | Screw-in type: thread dimension M68x2.0mm Roller clamp type: hole opening size Φ70mm |
Explosion Proof | Ex ia II AT3 (optional) |
Display | 4 bits LED display(LCD optional) |