Reliable TDS Sensors and Controllers for Purified Water, Drinking Water, Industrial Processes, and Treatment Systems

Reliable TDS Sensors and Controllers for Purified Water, Drinking Water, Industrial Processes, and Treatment Systems

Low-conductivity measurement from 0.01 to 20 µS/cm combines titanium electrodes, temperature compensation, logging, alarms, and digital communication for dependable purified-water monitoring and control apply.
Get a Free Quote

Different TDS Sensor and Meters for Sale

PCS3523 TDS Electrode
Inline TDS/conductivity electrode with four-electrode cell for accurate total dissolved solids measurement in RO permeate, boiler feed water, and drinking water distribution systems.
PT6500 Online TDS Meter Controller
A wall-mounted controller for continuous TDS monitoring and process control. It supports configurable current outputs, RS485 Modbus RTU, three relay groups, data logging, trend charts, and automatic or manual temperature compensation.

How to Choose Suitable TDS Sensors and Meters

Match the Measurement Range

Choose an electrode range close to expected conductivity; oversized ranges reduce sensitivity in purified-water applications.

Select the Cell Constant

Low-conductivity water requires a small cell constant, such as the PCS3523 electrode's K≈0.01.

Verify Material Compatibility

Check wetted materials against chemicals, cleaning agents, temperature, pressure, and long-term corrosion requirements.

Confirm Temperature Compensation

Select NTC10K, PT100, or PT1000 input matching the controller and operating-temperature range.

Plan Outputs and Control

Choose data logging, RS485, analog outputs, alarms, and relays according to monitoring and dosing requirements.

Relationship Between TDS and Conductivity and Measurement Tips

TDS is commonly estimated from electrical conductivity because dissolved ionic salts and minerals increase water's ability to conduct current. The meter applies a conversion factor to the temperature-compensated conductivity value, so TDS is not a direct identification of individual dissolved substances. For reliable results, select the correct electrode range and cell constant, use an application-appropriate conversion factor, calibrate with suitable standards, keep electrodes clean and fully immersed, remove trapped air, and compare readings at consistent reference temperatures during routine water monitoring.

Relationship Between TDS and Conductivity and Measurement Tips