Selecting a turbine flow meter begins with confirming that the liquid is clean, compatible, and sufficiently low in viscosity for stable rotor movement. Define the minimum, normal, and maximum flow rates before selecting meter diameter and range ratio. Then verify process temperature, pressure, connection type, wetted materials, installation orientation, and available straight pipe. Output requirements—including pulse, 4–20 mA, RS485, or HART—should match the control system. For explosive areas, confirm the required approval and electrical configuration before ordering the final meter.